Re: pa-mc-8t1 BERT fails

From: Ron Buchalski (rbuchals@hotmail.com)
Date: Sat Feb 05 2000 - 19:34:48 EST


>From: Brian Wallingford <brian@meganet.net>
>To: cisco-nsp@qual.net
>Subject: pa-mc-8t1 BERT fails
>Date: Sat, 5 Feb 2000 11:54:57 -0500 (EST)
>
>Hello,
>
>On a 7206 running 12.0(3)T, the BERT hardware seems to lock up after a
>single test. After completing one test pattern, attempting another
>pattern results in "% Bert hardware in use - command refused". A "sh
>contr t1 x/y" verifies the first test has ended, and "no bert" doesn't
>help.
>
>Any ideas?

Brian,

This is bug CSCdp04225. A fix was integrated into 12.0(7.03)T, so I'm not
sure whether it's in the 12.0(7)T code that's on CCO. Since 12.0T is now
EOE, there may never be a 12.0(8)T posted to CCO. In that case, going to
12.1 would pick up the bug fix.

It's also fixed in 12.0(8)S, which is available on CCO now.

-rb