RE: PA-2FEISL/load issue?

From: Michael K. Smith (mksmith@semaphore.com)
Date: Wed Sep 20 2000 - 19:43:17 EDT


What I was told by TAC at some point in the dim past was the PA-2FEISL-TX is
based on their old token ring cards and cannot handle full load across both
ports. If you need to do full duplex 100Mbit, they say you have to use the
PA-FE-ISL (or two of them for two connections). I have seen the 2 port fail
at higher loads.

Mike

Michael K. Smith -- CCNA, CCDA, CCNP
Senior Network Engineer Semaphore Corporation
NIC Handle: ms1986 2001 6th Ave Suite 400
mksmith@semaphore.com Seattle, WA 98121
206-905-5023 206-905-5000
----------------------------------------------------------------------
PGP Key Fingerprint - 92F3 3C34 34A2 6900 8F9C 9A35 6D2A D0A6 4846 3BE0
----------------------------------------------------------------------
 

-----Original Message-----
From: Larry Rosenman [mailto:ler@lerctr.org]
Sent: Wednesday, September 20, 2000 4:38 PM
To: cisco-nsp@puck.nether.net
Subject: PA-2FEISL/load issue?

A vendor of mine mentioned in passing that the PA-2FEISL-TX PA has an
issue with being driven above 60%. Has anyone got a reference on this
issue or some real-world experience?

Thanks!

LER

-- 
Larry Rosenman                      http://www.lerctr.org/~ler
Phone: +1 972-414-9812 (voice) Internet: ler@lerctr.org
US Mail: 1905 Steamboat Springs Drive, Garland, TX 75044-6749