RE: [nsp] BERT Tests

From: Subhendu Ghosh (sghosh@stevens-tech.edu)
Date: Wed Oct 11 2000 - 10:56:31 EDT


http://www.cisco.com/univercd/cc/td/doc/product/cable/cab_rout/cfig_nts/4815ds1p/4815conf.htm

Google is up: http://cisco.google.com/cisco

On Wed, 11 Oct 2000, Martin, Christian wrote:

> CCO Search Engine is down. A search on bgp returns document not found...
>
> -----Original Message-----
> From: Hank Nussbacher [mailto:hank@att.net.il]
> Sent: Wednesday, October 11, 2000 10:29 AM
> To: Ron.Fuller@3x.com
> Cc: cisco-nsp@puck.nether.net
> Subject: Re: [nsp] BERT Tests
>
>
> At 15:30 12/09/00 -0400, you wrote:
>
> A bit old, but what version supports bert command? Doing a search in Cisco
> shows 0 hits for the keyword bert.
>
> -Hank
>
> >Does anyone know the correct sequence of events required to run a BERT test
> >on a 7206VXR with the PA-MC-8T1 cards? When I run the BERT tests I get
> >errors that from what I see on CCO should be ignored. How do I know if the
> >BERT test was actually run properly? Here's an example:
> >
> >CC-7206-000-01(config)#cont t1 5/3
> >CC-7206-000-01(config-contro)#bert pattern 0s interval 10
> >CC-7206-000-01(config-contro)#end
> >CC-7206-000-01#sh cont t1 5/3
> >T1 5/3 is up.
> > Cablelength is long gain36 0db
> > DSX1 BERT pattern : zeros
> > DSX1 BERT sync : no sync
> > DSX1 BERT sync count : 0
> > DSX1 BERT interval : 10
> > DSX1 BERT time remain : 10
> > DSX1 BERT total errs : 23
> > DSX1 BERT total k bits: 0
> > DSX1 BERT errors (last): 0
> > DSX1 BERT k bits (last): 0
> > Applique type is Channelized T1
> > Description: Controller for the T-1 to Store #26
> > No alarms detected.
> > Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
> > Data in current interval (584 seconds elapsed):
> > 0 Line Code Violations, 0 Path Code Violations
> > 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
> > 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail
> Secs
> >
> >CC-7206-000-01#sh cont t1 5/3
> >T1 5/3 is up.
> > Cablelength is long gain36 0db
> > DSX1 BERT pattern : zeros
> > DSX1 BERT sync : no sync
> > DSX1 BERT sync count : 0
> > DSX1 BERT interval : 10
> > DSX1 BERT time remain : 10
> > DSX1 BERT total errs : 46
> > DSX1 BERT total k bits: 0
> > DSX1 BERT errors (last): 0
> > DSX1 BERT k bits (last): 0
> > Applique type is Channelized T1
> > Description: Controller for the T-1 to Store #26
> > No alarms detected.
> > Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
> > Data in current interval (593 seconds elapsed):
> > 0 Line Code Violations, 0 Path Code Violations
> > 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
> > 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail
> Secs
> >
> >We can see the total error counters increasing, but the status never goes
> >into sync. It always says no sync. Any suggestions or help would be
> >appreciated.
> >We are running IOS 12.0(6)S
> >
> >Ron Fuller, CCIE #5851, CCDP, CCNP-ATM, CCNP-Security, MCNE
> >3X Corporation
> >rfuller@3x.com
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:18 EDT