[nsp] Was: Re: [nsp] Cisco 7206-VXR disaster recovery.

From: Deepak Jain (deepak@ai.net)
Date: Mon Feb 26 2001 - 09:27:15 EST


Is there a way to write a 7200 or 7500 filesystem on a flash card from a
notebook's PCMCIA slot?

Thanks,

Deepak Jain
AiNET

On Mon, 26 Feb 2001, Barry Bruins wrote:

> If your router has no image on flash and no image on boot flash then
> you don't have a way to use tftp. The rommon doesn't have tftp in it.
> You will have to get a flash card with an image on it to boot from.
>
> Barry
>
>
> At 07:11 PM 2/26/2001 +0530, Vinod Anthony Joseph Cherunni wrote:
>
> >Dear David,
> >
> >Thanks so much for the reply, I tried connecting the TFTP server directly to the Fast-Ethernet interface on the NPE 300, & issued the command "boot c7200-js-mz.121-6.bin 192.168.1.1" I recieve the following error message
> >
> >" An alternate boot helper program is not specified (monitor variable "BOOTLDR" is not set) and unable to determine first file in boot flash load prog% error - on file open boot % cannot load "c7200-js-mz.121-6.bin 192.168.129.1".
> >
> >I do not find any vaild images on any of the flash disks, & the system is totally empty.
> >
> >I forgot to mention, that the router is currently stuck in ROM-Monitor mode.
> >
> >Kindly advise me on what could be done.
> >
> >With warm regards,
> >Vinod.
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:30 EDT