Re: [nsp] 65xx sup1a feature cards

From: Adam Rothschild (asr@latency.net)
Date: Tue Apr 03 2001 - 15:47:33 EDT


On Tue, Apr 03, 2001 at 03:03:29PM -0400, Martin Picard wrote:
> Both have MSFC2 installed. One came with the MSFC and
> the other one did not
> [...]
> With "show mod" I can see that the one shipped with the
> MSFC has "L3 Switching Engine WS-F6K-PFC"
> but the other one has "L2 Switching Engine II WS-F6020A"

Have you confirmed that both MSFC's are properly seated on the
Supervisor, and visible from CatOS (ie "show mod [15|16]", "session
[15|16]", etc)? This is sometimes an indication that they're not.

Unless you're handy with tools, I'd suggest trying to trade what you
have for a pre-assembled Sup+PFC+MSFC. Seating (and more importantly,
fastening) the MSFC is a bit more difficult than one would expect.

-adam