Re: [nsp] Cat2948G-L3 errors

From: Jared Mauch (jared@puck.nether.net)
Date: Thu Jan 17 2002 - 23:24:04 EST


        you may want to do 'logging buffered' and 'no logging console'
to prevent it from causing the system to halt when it's trying
to dump all the data out the console port at 9600bps

On Thu, Jan 17, 2002 at 03:10:45PM +0200, Elijah Kagan wrote:
> I am running 12.0(18)W5(22a) on Cat2948G-L3. Once every two to three days
> the switch becomes completely unusable and it repeats below error messages
> at a very high rate.
>
> %AAL5-3-RXERR: Flow Hdr: (10) input packet has wrong encap for input_if/input_idb as 0
> Cell Payload 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
> Cell Payload 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
> Cell Payload 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
> Cell Payload 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
>
> Does anyone have an idea what above messages mean? Is 2948G-L3 based on
> some ATM technology?
>
> -- elijah
>

-- 
Jared Mauch  | pgp key available via finger from jared@puck.nether.net
clue++;      | http://puck.nether.net/~jared/  My statements are only mine.