Re: [nsp] Router Reset problem

From: Basil V. Dolmatov (dol@east.ru)
Date: Fri Mar 27 1998 - 14:17:00 EST


> On Wed, 25 Mar 1998, Michael Smith wrote:
>
> > Hello All:
> >
> > I have a 7505 that, upon issuing the following commands, reboots itself with
> > a Bus error. I have a case open with TAC, but they have to hunt down a
> > particular programmer to decode the stac trace, and it may take several
> > days.
> >
> > Here it is:
> >
> > copy tftp start
> > copy start run
If you have problems with this kind of router crash, please, refer to TAC with bugID
CSCdj75432

Hope, it helps,
Basil
> >
> > I have about 100 PVC's on 7 serial ports and, upon issuing the copy ru sta
> > portion, I get about 90 "PVC already defined" messages and then it just
> > stops and reboots.
> >
> > We used to do configs on the router and then offload them to the tftp
> > server, but I'm trying put all the configs under revision control, so I
> > would prefer this method.
> >
> > Any help would be greatly appreciated!
> >
> > Mike
> >
> > Michael K. Smith
> > Senior Network Administrator - Northwest Link
> > (800) 390-1270
> > http://www.nwlink.com
> > mksmith@nwlink.com
> >
> >
>
> -------------------------------------------------------------------
> Scott Whyte swhyte@cisco.com |Any opinions expressed herein are
> Network Supported Accounts (NSA) |mine and not cisco's...
> CCIE 3340 |
> | "Eschew Obfuscation"
>

--------------------------------------
Basil (Vasily) Dolmatov dol@east.ru +7-095-956-4951
East Connection ISP, Moscow, Russia. (http://www.east.ru)

Nick handles ;) : BVD12, DOL1-RIPE, VVD2-RIPN



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:15 EDT