RE: [nsp] is it possible to have multiple HSRP Standby IP's????

From: Dan Friedman (dan@phunnyguy.com)
Date: Mon Jul 08 2002 - 09:17:49 EDT


uh ...not to interrupt...but how do i get off this mailing list.....my
address is nowhere to be seen and while what your talking about makes for
intresting reading, some of which i do actually understand...though very
little...i was wondering what we can do to get me off of this discussion
group list?

thanks

phunnyguy

-----Original Message-----
From: Ryan O'Connell [mailto:ryan-nsp@complicity.co.uk]
Sent: Monday, July 08, 2002 6:04 AM
To: Hagop Karaoghlanian; 'cisco-nsp@puck.nether.net'
Subject: Re: [nsp] is it possible to have multiple HSRP Standby IP's????

On Mon, 8 Jul 2002 08:43:34 -0400 Hagop Karaoghlanian
<hkaraoghlanian@corp.attcanada.ca> wrote:
> Hi All,
>
> Is it possible to have multiple standby IP's with two routers in one
> group?
>
> I have three different subnets in my LAN, a /29 and two /27's. I have a
> 2611 with dual T1, and another 2611 with a single T1. I need both of
> them
> passing traffic at the same time, I cannot have one of them dormant.
> But at
> the same time, they would both have to back each other up. Why both of
> them
> passing traffic? becuase dual T1 router has the 2 /27's on it, which is
> mostly internet traffic. The other router has the /29 on it used for
> VPN-ing and mail services.

Yes, have a look for MHSRP on CCO. (Multigroup HSRP)

http://www.cisco.com/univercd/cc/td/doc/cisintwk/ics/cs009.htm#xtocid122333

You can configure multiple groups with different standby IPs but the same
members, like this:(Apologies if I g et this wrong, I'm typing from memory
and not cut'n'pasting)

Router 1
--------
int FastEthernet0/0
  ip address 10.1.1.3 255.255.255.0
  standby 1 ip 10.1.1.1
  standby 1 priority 100 preempt
  standby 2 ip 10.1.1.2
  standby 2 priority 50 preempt

Router 2
--------
int FastEthernet0/0
  ip address 10.1.1.4 255.255.255.0
  standby 1 ip 10.1.1.1
  standby 1 priority 50 preempt
  standby 2 ip 10.1.1.2
  standby 2 priority 100 preempt

You then need to somehow ensure that different workstations on the network
use different default gateways.

In your situation, it's worth using standby track to peanalise any router
whose serial interfaces have gone down so all traffic automatically goes to
the working router.

--
         Ryan O'Connell - CCIE #8174
<ryan@complicity.co.uk> - http://www.complicity.co.uk

I'm not losing my mind, no I'm not changing my lines, I'm just learning new things with the passage of time



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:03 EDT