Re: [nsp] 7204VXR not recognizing FE interfaces

From: Stephen Sprunk (ssprunk@cisco.com)
Date: Tue Dec 11 2001 - 12:50:38 EST


Thus spake "Marius Strom" <marius@marius.org>
> Folks,
> Dealing with a brand-new out of the box 7204VXR with a c7200I/O-2FE/E
> board. The bootstrap recognizes the FE ports (12.1.8a-kboot), but
> putting a "normal" IOS image (tried with c7200-12.1-12-is56i-mz.bin) does
> not see the interfaces, and proceeds to give errors about environment
> monitoring (voltage levels, etc.). `show diag` gives a message about
> unknown Port Adapter type 533 in slot0, which is in fact the slot with
> the c7200I/O-2FE/E.

Check out:
http://www.cisco.com/cgi-bin/front.x/Support/HWSWmatrix/hwswmatrix.cgi/

      Product Family Product Number Minimum Supported Software Version(s)*
      7200 C7200-I/O-2FE/E= 12.0(14)S2, 12.1(3)E, 12.1(5)T, 12.2(1), 12.2(2)T

Your 12.1(12) will not support this card. 12.0S or 12.2 are the viable options in that list.

S