RE: [nsp] basement multihoming

From: Stephane Perez (perezs@nortelnetworks.com)
Date: Wed Jan 23 2002 - 03:55:31 EST


Hi,

 Some solutions for the backup purpose could be:

Use a higher MED value for the routes advertised to the backup BGP speaker

Use AS-Prepending for the routes of the other ISP advertised to the "normal"
preferred ISP. And the same for the routes advertised to the backup link. By
default all the BGP speakers consider the AS-Path in order to calculate the
local-preference and then the metric.

I hope this will help

regards

----------------------------------------------------------------------------
----------------------------------------------------------------------------
----------------
PEREZ Stephane
Carrier IP Specialist, Shasta GTS
Nortel Networks
ATS IP Core Infrastructure
25, allee Pierre Ziller
06560 Valbonne, FRANCE
Phone: +33 4 92 96 18 05 Mail : mailto:perezs@nortelnetworks.com
Fax : +33 4 92 96 16 68 www : http://www.nortelnetworks.com
Esn : 296-1805 Intranet :
http://hector.europe.nortel.com
ICQ : 120356046

-----Original Message-----
From: Charles Sprickman [mailto:spork@inch.com]
Sent: Tuesday, January 22, 2002 9:37 PM
To: cisco-nsp@puck.nether.net
Subject: [nsp] basement multihoming

Hi,

We currently have our own AS and a single upstream. Since we'd been
planning for quite some time to get a second upstream, we run BGP with our
existing upstream. We get a full table from them and announce our
netblocks to them.

We have made an agreement with another provider in the co-lo space to back
each other up... I'm wondering what my options are here; it's strictly
for backup purposes. I've considered announcing routes to both upstreams,
padding heavily to the backup, and doing a floating static default. Is
there really any point in taking two full views for this simple
configuration?

We connect to both upstreams via FE, and both hit a switch before the
router. In a situation where an upstream's router is down, but their
switch is up, would there be any way to detect that in my simplistic
floating static scenario?

Thanks,

Charles

| Charles Sprickman | Internet Channel
| INCH System Administration Team | (212)243-5200
| spork@inch.com | access@inch.com



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:29 EDT