I've got one here.
And, yes, I've searched cco, and yes, I've opened a ticket with the TAC;
both to no avail.
I've a Sup-1, MSFC2 6509 with two flexwan cards in it. One flexwan has two
pa-a3-oc3mm's, and the other has one PA-2T3 and one PA-2T3+.
We can't get the PA-2T3's to work; we're sure it's not the cards (we
tested them elsewhere), and we're sure it's not the flexwan (we swapped
with the one with the Pa-A3's, and it worked).
The interfaces are there, but no packets ever come 'in'. Even now, we have
a coax-hard-loop towards the card.
0 packets input, 0 bytes, 0 no buffer
45 packets output, 590 bytes, 0 underruns
We've tried PPP, HDLC, and Frame-relay.
12.1(8a)E5 running in native.
any tips, tricks, pointers? Anyone else seen this?
-- Alex Rubenstein, AR97, K2AHR, alex@nac.net, latency, Al Reuben --
-- Net Access Corporation, 800-NET-ME-36, http://www.nac.net --
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:29 EDT