Re: [nsp] Environmental Monitor initiated shutdown on UBR7246VXR

From: Mark Pace Balzan (mpb@melitacable.com)
Date: Thu Jan 31 2002 - 07:59:07 EST


The first line from you output shows you have exceeded bandwidth points in
your slots.

the 7206 requires that you calculate the points used by interfaces you use
in which slots.

You cannot put any amount of interfaces into any slot and expect it to work
well.
They have to be balanced across the two busses

Search cisco's site for the details of bandwidth points and which interfaces
to use in which slots and in which order

Mark

----- Original Message -----
From: "Tejal Shah" <tejal.shah@surat.iqara.net>
To: <cisco-nsp@puck.nether.net>
Sent: Thursday, January 31, 2002 1:52 PM
Subject: [nsp] Environmental Monitor initiated shutdown on UBR7246VXR

Hi all,

I am getting following error when i reboot my ubr7246VXR
CMTS with NPE-400.

========================================================
00:00:52: %SYS-3-LOGGER_FLUSHING: System pausing to ensure
console debugging output.

00:00:06: %UBR7200-3-CONFIG: Exceeds 600 bandwidth points
for slots 0, 1, 3 & 5
00:00:09: %LINK-3-UPDOWN: Interface FastEthernet0/0,
changed state to up
00:00:09: %LINK-3-UPDOWN: Interface GigabitEthernet1/0,
changed state to up
00:00:09: %LINK-3-UPDOWN: Interface Cable3/0, changed state
to up
00:00:09: %LINK-3-UPDOWN: Interface Cable4/0, changed state
to up
00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
FastEthernet0/0, changed state to up
00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet1/0, changed state to down
00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Cable3/0, changed state to up
00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Cable4/0, changed state to up
00:00:17: %LINEPROTO-5-UPDOWN: Line protocol on Interface
FastEthernet0/0, changed state to down
00:00:38: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Cable3/0, changed state to down
00:00:38: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Cable4/0, changed state to down
00:00:52: %UBR7200-0-TEMPHIGH: measured at 21C/69F is too
high: shutdown temperature 0C/32F
00:00:52: %ENVM-0-SHUT: Environmental Monitor initiated
shutdown
Buffered messageó
=========================================================

Pl. help me out to resolve this problem.

thanks in advance
Tejal Shah

Go To http://www.iqara.net



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:30 EDT