Not that I have ever worked with this particular varient of the 3500's. But
I get the sneaky suspicion that you need more than layer 2 to accomplish any
rate limiting.
Andrew
----- Original Message -----
From: "Elijah Kagan" <elijah@netvision.net.il>
To: <cisco-nsp@puck.nether.net>
Sent: Tuesday, February 05, 2002 11:21 AM
Subject: [nsp] Catalyst 3550
> Does anybody have an experience with Catalyst 3550? Specifically, I am
> trying to rate-limit traffic on a port in both direction.
>
> Here is what I've done:
> conf t
> mls qos
>
> class-map match-any ALL
> match any
>
> policy-map TEST
> class ALL
> police 96000 8000 exceed-action drop
>
> interface GigabitEthernet0/10
> service-policy input TEST
> service-policy output TEST
> end
>
> For some reason this does not work. The above configuration does not catch
> any traffic at all (this is confirmed by 'sh policy-map int gi 0/10').
>
> What have I done wrong?
>
> The switch is running layer-2 only software, version 12.1(6)EA1a.
>
> Any help will be greatly appreciated.
>
> Thanks,
>
> Elijah
>
>
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:31 EDT