Yes, missed one line while copying f0/0 configuration - "full-duplex". Of
course, both catalyst port and f0/0 on the router are in full-duplex mode.
Errors are coming in the following packs:
29 Align, 29 FCS, 12 Runts.
And, catalyst from time to time says:
1999 Nov 09 13:19:50 %PAGP-5-PORTTOSTP:Port 5/1 joined bridge port 5/1
1999 Nov 09 13:20:09 %PAGP-5-PORTTOSTP:Port 5/1 joined bridge port 5/1
and so on, thus I do assume that catalyst does also loose the connected
state from time to time.
Still, I'm in complete dark. ;(
SY,
-- (KD1350) CCNA Dmitri E. Kalintsev CDPlayer@irc Senior network engineer at NetActive Internet dek @ hades.uz phone: +27 (0)11 719-0333 fax: 444-8900 http://hades.uz UIN:7150410 cell +27 (0)82-336-1033
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:07 EDT