RE: [nsp] vrf on a native-mode Cat6k

From: Rolands Truls (Rolands@lattelekom.lv)
Date: Mon Feb 18 2002 - 08:02:27 EST


Hmm,
 Look at this:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/osm_in
st/mpls.htm#xtocid60604

Does anybody have a running MPLS VPN configuration for 7600 ?

>Limitations and Restrictions
>The following platform-specific limitations and restrictions apply to the
MPLS support on the OSM modules:

>Unsupported Features
>Limitations

>Unsupported Features
>Although the CLI may allow you to configure the following features, they
are not supported:

>MPLS-VPN
>MPLS-TE
>MPLS-CsC
>MPLS-InterAS-VPN

regards

rolands

-----Original Message-----
From: sthaug@nethelp.no [mailto:sthaug@nethelp.no]
Sent: pirmdiena, 2002. gada 18. februari 12:00
To: Rolands@lattelekom.lv
Cc: rkuhljr@uol.com.br; cisco-nsp@puck.nether.net
Subject: RE: [nsp] vrf on a native-mode Cat6k

> Are you sure, that it is work with OSM modules ?
> How far i know, MPLS VPN does not suported for cat65xx yet, just label
> switching/

A 6500 with OSM modules (and SUP2/MSFC2/PFC2) *is* a 7600. MPLS P and
PE functionality is available according to the docs.

Steinar Haug, Nethelp consulting, sthaug@nethelp.no

>
> regards
>
> rolands
>
> > -----Original Message-----
> > From: Rubens Kuhl Jr. [mailto:rkuhljr@uol.com.br]
> > Sent: Friday, February 15, 2002 7:38 PM
> > To: 'Steve Birnbaum'
> > Cc: cisco-nsp@puck.nether.net
> > Subject: RE: [nsp] vrf on a native-mode Cat6k
> >
> >
> >
> >
> > OSM Ethernet modules.
> > http://www.cisco.com/univercd/cc/td/doc/pcat/4pgietop.htm
> >
> >
> > Rubens
> >
> >
> > -----Original Message-----
> > From: Steve Birnbaum [mailto:sbirn@security.org.il]
> > Sent: Friday, February 15, 2002 2:31 PM
> > To: Kinczli Zoltin
> > Cc: cisco-nsp@puck.nether.net; fizquierdo@datagrama.net
> > Subject: Re: [nsp] vrf on a native-mode Cat6k
> >
> >
> >
> > > No, unfortunately it's not possible w/o additional hw.
> >
> > What hardware can be purchased that would allow this to
> > function while
> > still keeping the ethernet media on both sides as the ultimate
> > connections to the up/downstream devices?
> >
> > Thanks...
> >
> > Steve
> >
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:33 EDT