Re: [nsp] VIP4-80/PA issues, anyone?

From: Francois Baligant (francois@be.wanadoo.com)
Date: Tue Feb 19 2002 - 11:57:29 EST


        Anyone noticed that the CPU number keep changing
        after new VIP insertion in chassis and reload ?

        Anyone got a trick to glue a particular CPU number
        to a particular VIP ?

        regards,
        Francois

-- 

Francois Baligant _ Wanadoo Belgium NV/SA, Network Operation Center ( ) a subsidiary of France Telecom /_\/ Lozenberg 22 - B-1932 Zaventem francois@be.wanadoo.com (__/\ tel: +32 2 717 17 17 FB1-6BONE FB3122-RIPE fax: +32 2 717 17 77

- "if you hold a unix shell to your ear, do you hear the c?"

On Fri, 8 Feb 2002, Art Houle wrote:

> Mark, > > from our MRTG config files: > > Target[xxx-cpu12]: > 1.3.6.1.4.1.9.9.109.1.1.1.1.5.1&1.3.6.1.4.1.9.9.109.1.1.1.1.5.2:pwd@xxxx > > Target[xxx-cpu34]: > 1.3.6.1.4.1.9.9.109.1.1.1.1.5.3&1.3.6.1.4.1.9.9.109.1.1.1.1.5.4:pwd@xxxx > > I strongly recommend downloading Getif2.2. then place lotsa MIBs in > the > .....\getif\mibs\ directory (remove the .index file, then reload getif) > and do a 'walk' on > > 1.3.6.1.4.1.9.9.109.1.1.1.1.5 > > Art. > On Fri, 8 Feb 2002, Mark Boolootian wrote: > > > > > > be sure to monitor the VIP CPU utilization which will probably be higher > > > than the RSP. > > > > Speaking of which, does anyone happen to know if there is a MIB variable > > for VIP CPU utilization? > > > > Art Houle e-mail: houle@acns.fsu.edu. > Academic Computing & Network Services Voice: 850-644-2591 > Florida State University FAX: 850-644-8722 >



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:33 EDT