Thus spake Przemyslaw Karwasiecki (karwas@ifxcorp.com):
> I am using 12.0(18)ST and 12.0(19)ST1 and even when
> you can find subinterfaces in ifTable, they don't have
> ifInOctets and ifOutOctets counters.....
Support for this was added in 12.0(21)S so you night want to wait for
the equivalent ST train release.
> Somebody mentioned to me couple of months ago some workaround
> solution with monitoring some VLAN bridge groups, but I cannot
> recall any details.
The suggestion I remember was using CAR on a subinterface and then
monitoring using CISCO-CAR-MIB.
> Does it really means that there is no way to monitor bandwith on
> 802.1Q VLAN subinterfaces while using Service Provider trim????
The other workaround suggested was to use the output of sh vlan.from
the CLI....
Mark
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:37 EDT