Re: [nsp] Router crashing

From: Hagen Amen (hagena@multcolib.org)
Date: Fri Apr 19 2002 - 12:57:17 EDT


On Fri, 19 Apr 2002, Gert Doering wrote:

> Just as a side note. If this box happens to be a 4700M, it can actually
> take 64Mb of RAM.
>
> I forgot how to distinguish 4700 and 4700Ms, but it has to do with
> "revision X" in "show version":

Back on Tue, 22 May 2001, LaVonne Frank <lfrank@doit.wisc.edu> sent this
to cisco-nsp. I've used it successfully several times to ID this series
router (I still have 3 of them).

> I think this should help

> Cisco 4000 series processor revisions
> Router Revision
>
> 4000 0xA0
> 4000M 0xB0
> 4500 0x00
> 4500M B
> 4700 B
> 4700M C, D, E

-- 
Hagen Amen, Network Analyst
http://www.multcolib.org/