Re: [nsp] what cisco 7206 adapter is this?

From: Jared Mauch (jared@puck.nether.net)
Date: Wed Apr 24 2002 - 13:32:30 EDT


On Wed, Apr 24, 2002 at 01:30:45PM -0400, Eric Osborne wrote:
> On Wed, Apr 24, 2002 at 12:03:18PM -0400, Jared Mauch wrote:
> > Actually do
> >
> > 'sh diag'
> >
> > That's the easiest way to identify it.
> >
> > But based on what you have there, that looks like the
> >
> > PA-8T-V.35
>
> Really? I don't have one in the lab to check, but based on

        yeah, i was looking at the clock speed which made me think
it was a t1 pa.

> > > --begin--
> > > M2T-T3+ pa: show controller:
>
> I'd guess it's a PA-MC-2T3+ (first guess) or PA-2T3+ (second guess).

        sh diag <slot> will tell us for sure. that's a *lot* easier to read.

        - jared

>
>
>
>
> eric

-- 
Jared Mauch  | pgp key available via finger from jared@puck.nether.net
clue++;      | http://puck.nether.net/~jared/  My statements are only mine.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:42 EDT