Has anyone experienced a sporadic authorization failure to a Catalyst 6509,
using TACACS+?
We have found that sometimes you have to do a login attempt up to 6(six)
times to get an enable prompt.
This works perfectly when using IOS based equipment, (routers AND switches)
Tacacs server is
Form the FREEtacacs server:
------------------------------------------
user = admin {
default service = permit
login = des xxxxxxxxxxxx
service = exec {
priv-lvl = 15
}
}
From the Catalyst 6509
----------------------------------
WS-C6509 Software, Version NmpSW: 6.1(1b)
Copyright (c) 1995-2000 by Cisco Systems
NMP S/W compiled on Nov 9 2000, 22:11:25
set tacacs server xxx.xxx.xxx.xxx
set tacacs attempts 3
set tacacs directedrequest disable
set tacacs key <secret>
set tacacs timeout 10
#authentication
set authentication login tacacs enable console primary
set authentication login tacacs enable telnet primary
set authentication login tacacs disable http
set authentication enable tacacs enable console primary
set authentication enable tacacs enable telnet primary
--------------------------------------------------------------------------------------------------------
Robert Frånberg E-Mail: robert.franberg@it.su.se
Stockholms universitet Tel: 08 - 674 7594
Enheten för IT och media Mobil: 070- 620 7594
106 91 Stockholm