We had this happen with a PA-A3-OC3MM today in a 7206VXR/400/2FE, the card
is not recognized in the slot 2 but works fine in slot 6 (same PCI bus). We
reinserted the card multiple times and still came up with the error. Defect
slot?
May 21 13:24:59.244 UTC: %OIR-6-INSCARD: Card inserted in slot 2, interfaces
administratively shut down
May 21 13:25:00.244 UTC: %C7200-4-PCIVALID: PCI activation failed, bay 2,
0x11113104
May 21 13:25:00.916 UTC: %PA-2-UNDEFPABRIDGE: Unsupported Port Adaptor
Bridge 0xFFFFFFFF in bay 2
May 21 13:25:00.916 UTC: %PA-3-DEACTIVATED: port adapter in bay [2] powered
off.
May 21 13:25:00.916 UTC: %PA-2-PABRIDGE: Failed to config bridge for PA 2
Slot 2:
Fast-ethernet port adapter, 1 port
Port adapter is disabled deactivated
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware revision 0.0 Board revision UNKNOWN
Serial number 0 Part number 00-0000-00
Test history 0x0 RMA number 00-00-00
EEPROM format version 0
EEPROM contents (hex):
0x20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0x30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Thomas
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:44 EDT