Re: [nsp] GSR code releases.

From: Danny McPherson (danny@qwest.net)
Date: Sun Nov 28 1999 - 11:10:45 EST


> what probs have you experienced with 12.0(7)S ??

Several of those listed below caused problems during our lab testing...

7.1.S
     CSCdp11868 2 Frame relay outgoing DLCI EA filed is incorrectly set
     CSCdp11949 5 %SUBSYS-2-BADSEQUENCE: Subsystem (rttmon).. (ipdiag)
     CSCdp12228 2 GEIP: interface stays up when remote is down or fiber is cut
     CSCdp14055 1 dWFQ+CT3PA/2CT3PA: VIP crashes at hqf_svip_ifc_dtq_consumer()
     CSCdp14088 2 Frame relay switching works only on first Jaguar port
     CSCdp14229 2 Deluxe: CLP bit not set w/ Rev 1.0 PA-A3
     CSCdp14672 3 Size of structure copied is wrong
     CSCdp15270 1 Atm interface has wrong sdh framing
     CSCdp15373 3 Signalling changes for handling Async driver interface
     CSCdp15498 3 Optimize perf engine tx slow path for tbm < version 6
     CSCdp15612 3 MPLS TE: Config. of tunnel path option, verbatim, is
inconsistent
     CSCdp15675 2 Flow based dWFQ not invoked on sub-int(1st feature in 1st
class)
     CSCdp15855 2 dWFQ: traffic stops after enabling fair-queue on CT3
interface
     CSCdp15950 3 MPLS TE: inprogress BW is not cleared when TE Fragments are
used
     CSCdp15994 2 APS/PMC framers: traffic passed by deselected port
     CSCdp16181 4 Add new FCI type to Constellation WAN cards.
     CSCdp16460 3 llq : clear counters does not clear stats for class-default
     CSCdp16567 3 MRM: Status report acknowledge packet is not recognized
     CSCdp17463 3 MerlinPA:srp ips request forced-switch should be saved to
NVRAM
     CSCdp18538 2 GSR: GE netflow crash
     CSCdp18540 2 GDB broken, drops to ROM.
     CSCdp18677 3 WRED: Getting out of wred does not remove config
     CSCdp18754 3 CAR: incorrect dscp value set by rate-limit
     CSCdp18850 3 TFIB error message is poorly placed/used
     CSCdp19536 2 %GENERAL-3-EREVENT: Tag rewrite does not point to any psa
     CSCdp19715 4 Enhancement - tracing of mbus messages
     CSCdp19804 2 Perf-OC48-LC crash in bflc_intr_dispatch
     CSCdp19922 3 DDTS sync broke svip.c
     CSCdp20323 3 CISCO-SYSLOGMIB missing from gsr images
     CSCdp21246 3 clns dynamic hostname does not work with sh isis top
hostname
     CSCdp21558 1 Router crashes during NVGEN with SegV exception
     CSCdp22249 2 Basic Tag does not work on QOC12 ATM (Inuit) card
     CSCdp22281 3 MPLS-TE: requires PRIV_CONF
     CSCdp22636 3 FR counter is not working right
     CSCdp22785 3 MPLS-TE: memory corruption in lsa handling
     CSCdp22943 3 MPLS:tfib ui damage syncing connecticut:V120_7_1
     CSCdp23156 3 Merlin: Fairness correction (MAC FPGA 296 update)
7.3.S
     CSCdk21804 3 IGMP v2 leave message not sent on wire
     CSCdk69667 3 tag-range command not fully effective
     CSCdk94035 3 Expected VC failed to come up after timeout - vc in_pkts
doublecount
     CSCdm20166 3 Output FR PVC counters broke for CEF/DCEF
     CSCdm22068 3 Traceback found during reload of c4000-js-mz in snmp
     CSCdm25948 2 CT3: Failed to configure the CT3PA if MC2T3/CT3IP OIR out
     CSCdm34936 2 OUTPUT STUCK on Channelised E1 ports
     CSCdm42603 4 command doesnt work: show tag tdp bind remote-tag
     CSCdm48924 2 Router crash with ISIS displaing the output of show isis top
     CSCdm63603 5 Output of show gsr slot-state-trace is ugly
     CSCdm64405 3 APS: jumbo patch
     CSCdm65646 3 TIMERNEG traceback setting tdp holdtime.
     CSCdm72607 3 New feature: VP Shaping
     CSCdm76584 5 PA config exceeds aggregate bandwidth NOT!
     CSCdm80689 4 Merlin: Remove unsupported config commands from SRP CLI
     CSCdm82546 2 Performance cards cannot loadbalance between ip and tag
adjacencies
     CSCdm83004 3 Optimization needed for default route calculation
     CSCdm89293 3 Fast EtherChannel for 7200
     CSCdm90569 3 On GSR POS with large MTU, packetsize is limited to 4538
bytes
     CSCdp04225 3 POTENT: BERT was refused to run on the 2nd test
     CSCdp05571 2 Access Control Lists Statistics not accessable
     CSCdp11190 3 Need to restrict multicast streams in backbone switches
(RGMP)
     CSCdp11442 2 MerlinPA: problem with fairness
     CSCdp14018 3 GSR: 802.1Q needs to check port number on input packets
     CSCdp15126 2 DCEF policy routing with FE ISL subinterface does not work
     CSCdp16403 1 RSP8: TIGER-3-SBE_LIMIT: Single bit error detected
     CSCdp16815 3 CEF load balancing hash bucket counters wrong
     CSCdp20767 3 GSR+: Configuration ip address does not get to linecard
     CSCdp21098 3 dTS: police does not work with match ip prec
     CSCdp21343 2 OC-12 ATM VC rates are 0, states stay at INACTIVE
     CSCdp21424 2 POTENT needs to protect critical regions with correct
priority level
     CSCdp21739 2 atm reset bandwidth causes eigrp remove connected route
     CSCdp22804 3 GSR Inuit: %LC-3-BMAERRS: ToFab BMA BMA error status error 1
     CSCdp23390 5 mbus trace enhancement - display MFR addresses
     CSCdp24026 5 CAR: input rate counter doubles with rate limit statement
     CSCdp24774 3 MPLS:bad handling of fddi-in ip2tag mtu exceeded packets
     CSCdp25428 3 Over 128 VCs in a single deluxe queue causes VC not
transmittable
     CSCdp26222 2 rsp build broken by CSCdm30633
     CSCdp26596 3 MPLS TE: tunnels not torn down properly when tailend RTR ID
removed
     CSCdp26616 3 MPLS TE: RRR LM doesnt properly notify IGP when area removed
     CSCdp26716 2 GE:802.1q: Failed to add address 0000.0c07.ac62 to CAM
     CSCdp26883 2 MerlinPA: Change of IP address in SRP int not updated in
trace buf
     CSCdp27183 2 RSVP drops message if reserved header bit is set
     CSCdp28202 5 LC_PLATFORM_GENERATION_[5,6]
     CSCdp28761 3 MPLS TE: tunnel show command can print empty string for
tunnel name
     CSCdp28779 2 POS mgd_timer traceback occurs on GE card
     CSCdp29573 3 Merlin: Change of IP address in SRP not updated in trace buf
     CSCdp31259 1 Performance OC48 fabric loader broken
     CSCdp31471 2 ABR: PA-A3 - Bad SAP received 0000 error from forward RM cell
     CSCdp31475 2 Router crash when configuring CAR
     CSCdp31552 3 BFR_CARD_TYPE_3P_GE and BFR_CARD_TYPE_3P_GE_BIT
     CSCdp32090 2 POS alarm delay timer - error msgs on QOC12
     CSCdp33008 3 init gsr16 alarm outputs
     CSCdp33110 3 GSR Inuit: Umbrella patch (11/09/99)



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:08 EDT