A rolled cable using pins 1/2 and 4/5 end to end for T-1 and set the network
clock of one CSU/DSU to internal/master.
Jeff
----------------------------------------------------------
Jeff Tarkington, Internetworking Consultant
eB Networks
5511 Capital Center Drive
Suite 600
Raleigh, NC 27606
www.ebnetworks.com eB Networks - Leading the way to eBusiness - at NetSpeed!
-----Original Message-----
From: Steve Pfister [mailto:srp336@optimum.com]
Sent: Monday, December 20, 1999 1:09 PM
To: cisco-nsp@puck.nether.net
Subject: Serial line troubleshooting
I've got a new T1 installation that I can't seem to find the problem with.
I'd like to be able to eliminate T1 misconfiguration as the source of the
trouble. Can I connect the CSU/DSUs together with a straight-through cable
to verify that the hardware on both ends is working properly? Or do I need
some other sort of cable?
Thanks!
--Steve
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:08 EDT