Hi Cisco Gurus,
I'm busy with the replacement of a C2501 by a C2610 with a 4 Serial in Slot1.
Cisco is connected to a 7206. I just replaced the C2501 with the C2610
and plugged the same cables etc... (both router have the same IP, routes, ...)
Problem: The line is up but the protocol is going up/down every mins.
I also get a very high numbers of errors! Any idea?
On the 7206:
Serial4/0 is up, line protocol is up
Hardware is M4T
Interface is unnumbered. Using address of FastEthernet0/0 (a.b.c.d)
MTU 1500 bytes, BW 512 Kbit, DLY 20000 usec, rely 185/255, load 1/255
Encapsulation HDLC, loopback not set, keepalive set (10 sec)
Last input 00:00:04, output 00:00:00, output hang never
Last clearing of "show interface" counters 00:39:11
Input queue: 0/75/0 (size/max/drops); Total output drops: 0
Queueing strategy: weighted fair
Output queue: 0/64/0 (size/threshold/drops)
Conversations 0/258 (active/max active)
Reserved Conversations 0/0 (allocated/max allocated)
5 minute input rate 2000 bits/sec, 3 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
3264 packets input, 254842 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 4 giants
3619 input errors, 954 CRC, 0 frame, 0 overrun, 0 ignored, 2665 abort
2344 packets output, 204378 bytes, 0 underruns
0 output errors, 0 collisions, 57 interface resets
0 output buffers copied, 0 interrupts, 0 failures
57 carrier transitions DCD=up DSR=up DTR=up RTS=up CTS=up
!
interface Serial4/0
ip unnumbered FastEthernet0/0
ip accounting output-packets
bandwidth 512
!
On the 2610:
Serial1/0 is up, line protocol is up
Hardware is CD2430 in sync mode
Interface is unnumbered. Using address of Ethernet0/0 (e.f.g.h)
MTU 1500 bytes, BW 512 Kbit, DLY 20000 usec,
reliability 128/255, txload 1/255, rxload 1/255
Encapsulation HDLC, loopback not set, keepalive set (10 sec)
Last input 00:00:05, output 00:00:00, output hang never
Last clearing of "show interface" counters 00:39:15
Input queue: 0/75/0 (size/max/drops); Total output drops: 0
Queueing strategy: weighted fair
Output queue: 0/1000/64/0 (size/max total/threshold/drops)
Conversations 0/3/256 (active/max active/max total)
Reserved Conversations 0/0 (allocated/max allocated)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
146 packets input, 11046 bytes, 0 no buffer
Received 37 broadcasts, 0 runts, 2 giants, 0 throttles
2124 input errors, 761 CRC, 0 frame, 1349 overrun, 0 ignored, 14 abort
6233 packets output, 502884 bytes, 2321 underruns
2321 output errors, 0 collisions, 80 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions
DCD=up DSR=up DTR=up RTS=up CTS=up
!
interface Serial1/0
ip unnumbered Ethernet0/0
no ip directed-broadcast
bandwidth 512
!
-- Visit: http://3276456082 "Contrary to popular belief, Unix is userfriendly. It just happens to be selective about who it makes friends with."
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:08 EDT