Re: [nsp] [nsp] 6500 port based security and management

From: Neil J. McRae (neil@COLT.NET)
Date: Mon Jan 24 2000 - 10:31:22 EST


On Mon, 24 Jan 2000 04:32:50 -0500
 "Desmarais, Jonathan" <JDesmarais@colt-telecom.com> wrote:

> 2. The same 6509 have two Supervisor modules, each of which has an MSFC
> router card attached. All devices are connected to a management LAN lets
> call it A. They are either directly connected or through a common Vlan which
> is part of the same LAN. All are accessed via the LAN A address by snmp,
> except the MSFC cards. The are being sourced by their public addresses, the
> addresses we configured first. I though perhaps Ciscoworks was accessing the
> first address in the config, however that is not the case. Is their
> something that can be configured in CISCO works or the router cards that
> will enable us to access the LAN A address for snmp queries?

Add an interface to the MSFC router engines onto LAN A.

Regards,
Neil.

--