Re: pa-mc-8t1 BERT fails

From: Jesper Skriver (jesper@skriver.dk)
Date: Sat Feb 05 2000 - 12:10:31 EST


On Sat, Feb 05, 2000 at 11:54:57AM -0500, Brian Wallingford wrote:
> Hello,
>
> On a 7206 running 12.0(3)T, the BERT hardware seems to lock up after a
> single test. After completing one test pattern, attempting another
> pattern results in "% Bert hardware in use - command refused". A "sh
> contr t1 x/y" verifies the first test has ended, and "no bert" doesn't
> help.
>
> Any ideas?

Upgrade to 12.0(7)T, there has been LOTS of bugs in 12.0(x)T, there is a
good chance it's fixed ...

/Jesper

-- 
Jesper Skriver, jesper(at)skriver(dot)dk  -  CCIE# 5456
Work:    Network manager @ AS3292 (Tele Danmark DataNetworks)
Private: Geek            @ AS2109 (A much smaller network ;-)

One Unix to rule them all, One Resolver to find them, One IP to bring them all and in the zone to bind them.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:09 EDT