Hi
Got a problem ;-(
I'm doing OSPF nssa on the edge of my backbone area 0.0.0.0, and
I've got same design/config other places witch is working. But
on this R1 and R2 it is not working, routes from R3 are not
redistributed into area 0.0.0.0 ..... means I cannot see the static
routes and connected subnets in R3, from my backbone area 0.0.0.0, but
I can see everything from R1 and R2.
If I'm doing OSPF widthout nssa it works ;-(
Any idea
| area 0.0.0.0 |
------- -------
| R1 |-----------------| R2 |
------- -------
\ /
\ area 3.0.0.10 /
\ ------- /
--- | R3 | ---
-------
Link from R1 to R2 are in area 0.0.0.0, and a tunnel for area 3.0.0.10
setup is on the ABR's is
R1
ver. 12.0(10)S
router ospf xxxx
area 3.0.0.10 nssa no-redistribution default-information-originate
redistribute connected subnets
redistribute static metric-type 1 subnets
network 130.227.1.140 0.0.0.3 area 0.0.0.0
network 130.227.1.112 0.0.0.7 area 0.0.0.0
network 130.227.1.196 0.0.0.3 area 3.0.0.10
network 130.227.1.168 0.0.0.3 area 3.0.0.10
R2
ver. 12.0(6.5)S1
router ospf xxxx
area 3.0.0.10 nssa no-redistribution default-information-originate
redistribute connected subnets
redistribute static metric-type 1 subnets
network 130.227.1.112 0.0.0.7 area 0.0.0.0
network 130.227.1.144 0.0.0.3 area 0.0.0.0
network 130.227.1.196 0.0.0.3 area 3.0.0.10
network 130.227.1.132 0.0.0.3 area 3.0.0.10
R3
on the nssa router
router ospf xxxx
network 130.227.1.168 0.0.0.3 area 3.0.0.10
network 130.227.1.132 0.0.0.3 area 3.0.0.10
area 3.0.0.10 nssa
--Jan
UNI2 / get2net _/_/_/_/ _/_/_/ _/ _/_/_/ _/_/_/_/
TELE2 A/S _/ _/ _/ _/ _/
Gl. Koege Landevej 55 _/ _/_/ _/ _/_/ _/_/_/_/
DK-2500 Valby _/ _/ _/ _/ _/
_/ _/_/_/ _/_/_/ _/_/_/ _/_/_/_/ _/
E-mail: jo@uni2.dk URL : http://www.uni2.dk/ Phone: (+45) 77301200
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:13 EDT