there is no "+" version of the 1 port mc-t3 cards. the "+" version only
exists for the 2 port cards, and yes they do support sub-rate T3s which
is not supported on the 1 port cards. the sub-rate support however is
a sw feature that is not available today, but is on the roadmap.
regards
.siva
>
> Plus version supports sub-rate t3's (aka fractional t3). I don't think
> there was an upgrade program, it's not something to get excited about
> unless your provider offers offers cheap channelized sub-rate t3's. 8-)
>
> > Date: Fri, 9 Jun 2000 01:12:41 -0700 (PDT)
> > From: Joe McGuckin <joe@via.net>
> > To: cisco-nsp@puck.nether.net
> > Subject: PA-MC-2T3 question
> >
> > I have a unit that says "Multi-channel T3" on the faceplace. The cisco
> > website shows a faceplate that says "Multi-Channel 2T3+" .
> >
> > Was there a non 'plus' version of this port adaptor?
> >
> > Is there an upgrade program ?
> >
> > Thanks,
> >
> > Joe
> >
> >
>
>