> I have a Catalyst 6509 with a Local Director configured for ASLB. The ASLB
> part of it works fine, however if I try to telnet (not an local directed
> service) to the REAL address of one of the load balanced machines the
> session takes about 2 minutes to connect.
>
A guess would be the TCP wrappers have some problem doing a reverse
lookup on your connection if its being proxied through the Local director
and the LD has no reverse DNS.
Regards,
Neil.