RE: [nsp] 8 Port ISDN BRI Module

From: Basil Dolmatov (dol@east.ru)
Date: Mon Jul 24 2000 - 04:11:14 EDT


We have had this card for a year, until get full PRI.
Worked OK, no issues, but... We work with switch-type
"basic-net-3", so, no SPIDs at all...

--------------------------------------------------------
Basil (Vasily) Dolmatov, CCIE #5347, CCNP-Security, CCDA
LightCom Corp. http://www.lightcom.ru

> -----Original Message-----
> From: Steve Yingst (LMF Staff) [mailto:runner@lmf.net]
> Sent: Saturday, July 22, 2000 2:13 AM
> To: cisco-FAQ
> Subject: [nsp] 8 Port ISDN BRI Module
>
>
> Does anyone have experience with the 8 Port BRI Module in either a 2600 or
> 3600 series router. We thought we were going to put this module
> in and get
> rid of all of our Cisco 804 routers. That are doing 4 digit
> dialing to 804
> routers at the customers side. It was a good theory. But
> either we have
> a bad card/bad configuration or they have a bad design. Only
> one SPID will
> initialize on the
> card as Multiple_Frame_Established, the other one never makes it to that
> part on the show isdn stat. If anyone has one either the 8 port
> or 4 port
> module successfully running I would be eternialy greatful if I could see
> your config. Cisco was in looking at the router and said it seems like
> it's an issue with the telco, switch. So I plugged it back into my 804
> router and the both SPIDs came up multiple_frame_established and
> worked dual
> channel. So that pretty much rules out the line being physically
> bad. Any
> ideas would be greatly appreciated.
>
> Steve
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:14 EDT