RE: [nsp] CEF subinterface

From: Rick Payne (rickp@rossfell.co.uk)
Date: Sat Aug 26 2000 - 03:17:40 EDT


--On 25/08/00 12:52:13 -0400 "Martin, Christian" <cmartin@gnilink.net>
wrote:

> A cisco defect has been logged in regards to this issue. I spoke with the
> developer, who verified the problem. Apparently, while implementing the
> BGP Policy MIB, the DEs latched into the CEF sublayer instead of the
> actual interface. It will likeley be removed in the 12.1 train, and
> maybe some 12.0S images. (13?)

Thats a shame - 'cos its the only way I've found to accurately map the
interface numbers used in the netflow export to the "real" interfaces on
the router.

If the "CEF-layer" SNMP interfaces are to be removed - whats the
recommended method for mapping netflow interface ID to real interfaces?

Rick