Re: [nsp] Unequal loaad balancing.

From: Andrew (arousch@home.com)
Date: Fri Sep 08 2000 - 00:37:01 EDT


why not just have the 2M a primary link and the 512k backup and use a
floating static for the 512k. If you are already planning on the need for
the extra 512k pipe then you should look at getting a bigger connection to
begin with.

At 09:24 AM 9/8/00 +0800, nick wrote:
>We have two links to our ISP upstream provider; 512k and 2M. Each of these
>links is connected to BR1 and BR2 respectively. These links are also
>connected to separate routers at the same upstream provider.
>
>We are running OSPF internally and have just got our AS number and thinking
>of running BGP soon. Any ideas on how to efficiently load balance these
>links both with and without running BGP?
>
>Thanks in advance.
>
>Nick



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:16 EDT