Re: PA-T3 Adapter Installation

From: Andy Walden (andy@tigerteam.net)
Date: Wed Sep 27 2000 - 10:41:47 EDT


This may work:

controller T3 2/0
 clock source line
 t1 1 channel-group 0 timeslots 1-12
 t1 2 channel-group 0 timeslots 1-12
 t1 3 channel-group 0 timeslots 1-12
 t1 4 channel-group 0 timeslots 1-12
 t1 5 channel-group 0 timeslots 1-12
 t1 6 channel-group 0 timeslots 1-12
 t1 7 channel-group 0 timeslots 1-12
 t1 8 channel-group 0 timeslots 1-12
 t1 9 channel-group 0 timeslots 1-12
 t1 10 channel-group 0 timeslots 1-12
 t1 11 channel-group 0 timeslots 1-12
 t1 12 channel-group 0 timeslots 1-12

Regards,
andy

On Wed, 27 Sep 2000, Steven Griffin wrote:

> When using only a portion of a T3 what are the commands used in the interface to tell the DSU what channels to use? For example on a WIC-1DSU half a T1 would be SERVICE-MODULE T1 TIMESLOTS 1-12. Is there an equivalent for the PA-T3? The documentation I have reviewed only talks about the bandwidth command.
>
> SG
>
>
>