This may work:
controller T3 2/0
clock source line
t1 1 channel-group 0 timeslots 1-12
t1 2 channel-group 0 timeslots 1-12
t1 3 channel-group 0 timeslots 1-12
t1 4 channel-group 0 timeslots 1-12
t1 5 channel-group 0 timeslots 1-12
t1 6 channel-group 0 timeslots 1-12
t1 7 channel-group 0 timeslots 1-12
t1 8 channel-group 0 timeslots 1-12
t1 9 channel-group 0 timeslots 1-12
t1 10 channel-group 0 timeslots 1-12
t1 11 channel-group 0 timeslots 1-12
t1 12 channel-group 0 timeslots 1-12
Regards,
andy
On Wed, 27 Sep 2000, Steven Griffin wrote:
> When using only a portion of a T3 what are the commands used in the interface to tell the DSU what channels to use? For example on a WIC-1DSU half a T1 would be SERVICE-MODULE T1 TIMESLOTS 1-12. Is there an equivalent for the PA-T3? The documentation I have reviewed only talks about the bandwidth command.
>
> SG
>
>
>
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:17 EDT