RE: Problems with a PA-POS card

From: Mike Gibbs (gibbs@servint.com)
Date: Thu Oct 19 2000 - 13:16:44 EDT


Adding to this, all the routers I use, on 2 different OC-3 lines are
saying the same thing. IS there a bad batch of OC-3 cards?

On Thu, 19 Oct 2000, Martin, Christian wrote:

> Mike,
>
> You are getting a high number of BIP3 errors. This is generally caused by
> bad transmit at the far end, or a problem in the carrier network.
>
> Regards,
> chris
>
>
>
>
>
>
> > -----Original Message-----
> > From: Mike Gibbs [mailto:gibbs@servint.com]
> > Sent: Thursday, October 19, 2000 10:30 AM
> > To: cisco-nsp@puck.nether.net
> > Subject: Problems with a PA-POS card
> >
> >
> >
> > What would cause these errors? I assumed it was light
> > intensity too high,
> > since the telco sent us -12.2 dBm so we built it out to -23
> > dBm and are
> > getting the same errors.
> >
> >
> > *Oct 18 17:32:38: %SONET-4-ALARM: POS8/0/0: B3 BER exceeds
> > threshold, TC alarm declared
> > *Oct 18 17:32:48: %SONET-4-ALARM: POS8/0/0: B3 BER below
> > threshold, TC alarm cleared
> > *Oct 18 17:40:46: %SONET-4-ALARM: POS8/0/0: B3 BER exceeds
> > threshold, TC alarm declared
> > *Oct 18 17:40:56: %SONET-4-ALARM: POS8/0/0: B3 BER below
> > threshold, TC alarm cleared
> > *Oct 18 17:46:48: %SONET-4-ALARM: POS8/0/0: B3 BER exceeds
> > threshold, TC alarm declared
> > *Oct 18 17:46:58: %SONET-4-ALARM: POS8/0/0: B3 BER below
> > threshold, TC alarm cleared
> > *Oct 18 18:04:09: %SONET-4-ALARM: POS8/0/0: B3 BER exceeds
> > threshold, TC alarm declared
> >
> >
> > Cisco Internetwork Operating System Software
> > IOS (tm) RSP Software (RSP-K3PV-M), Version 12.0(9)S, EARLY DEPLOYMENT
> > RELEASE SOFTWARE (fc1)
> > Copyright (c) 1986-2000 by cisco Systems, Inc.
> > Compiled Fri 04-Feb-00 20:18 by htseng
> > Image text-base: 0x60010908, data-base: 0x60D2E000
> >
> > ROM: System Bootstrap, Version 11.1(8)CA1, EARLY DEPLOYMENT RELEASE
> > SOFTWARE (fc1)
> > BOOTFLASH: GS Software (RSP-BOOT-M), Version 11.1(22)CA,
> > EARLY DEPLOYMENT
> > RELEASE SOFTWARE (fc1)
> >
> > Telephonica uptime is 1 week, 1 day, 20 hours, 1 minute
> > System returned to ROM by reload
> > System image file is "slot0:rsp-k3pv-mz_120-9_S.bin"
> >
> > cisco RSP4 (R5000) processor with 262144K/2072K bytes of memory.
> > R5000 CPU at 200Mhz, Implementation 35, Rev 2.1, 512KB L2 Cache
> > Last reset from power-on
> > G.703/E1 software, Version 1.0.
> > G.703/JT2 software, Version 1.0.
> > X.25 software, Version 3.0.0.
> > Chassis Interface.
> > 1 GEIP controller (1 GigabitEthernet).
> > 1 VIP2 R5K controller (1 POS).
> > 1 GigabitEthernet/IEEE 802.3 interface(s)
> > 1 Packet over SONET network interface(s)
> > 123K bytes of non-volatile configuration memory.
> >
> > Mike Gibbs
> >
>

Mike Gibbs



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:19 EDT