Has anyone come across PA-T3 interfaces that stop responding to the
router? Even if I re-insert the interface it's detected but I get
the same error messages.
%MUESLIX-1-STOPFAIL: Mx serial, Serial2/0 Stop Failed at disable port
%MUESLIX-1-STARTFAIL: Mx serial, Serial2/0 Start Failed at enable port
no errors on the interface (line is up) but it doesn't respond.
Serial2/0 is up, line protocol is up
Hardware is M1T-T3 pa
Internet address is x.x.x.x/x
MTU 4470 bytes, BW 44210 Kbit, DLY 200 usec, rely 255/255, load 1/255
Encapsulation HDLC, crc 16, loopback not set
Keepalive set (10 sec)
Last input 00:00:05, output 03:05:18, output hang never
Last clearing of "show interface" counters 00:21:23
Queueing strategy: fifo
Output queue 0/40, 40 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
128 packets input, 3072 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 parity
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
114 packets output, 3120 bytes, 0 underruns
0 output errors, 0 applique, 1 interface resets
0 output buffer failures, 0 output buffers swapped out
2 carrier transitions
rxLOS inactive, rxLOF inactive, rxAIS inactive
txAIS inactive, rxRAI inactive, txRAI inactive
Thomas