Re: PA-T3 interface not responding

From: Thomas Kernen (tkernen@deckpoint.ch)
Date: Thu Oct 26 2000 - 09:35:24 EDT


Well a 7206VXR with 12.0(12)S and 2x PA-T3 isn't much. Only one card got
out of sync the other was fine. I finally rebooted the box and it solved
the problem. Seems that I don't have much luck with VXRs :(

Thomas

George Robbins wrote:
>
> We used to get those a lot on HSSI cards, it seems to be basically a case
> where the software gets out of sync with the hardware and can't get it
> going again.
>
> For the PA-H's, just pulling out the card and re-inserting it was enough
> to get it going again, though rebooting was also effective. 8-(
>
> I think contributing factors were having too many cards in the router,
> some of which were CT3-PA's. There have also been verious IOS bugs
> causing this, but if you're running something curreint in 11.1CC, or
> 12.x you shouldn't be seeing those...
>
> regards; George
>
> > Date: Thu, 26 Oct 2000 14:54:22 +0200
> > From: Thomas Kernen <tkernen@deckpoint.ch>
> > Subject: PA-T3 interface not responding
> >
> >
> > Has anyone come across PA-T3 interfaces that stop responding to the
> > router? Even if I re-insert the interface it's detected but I get
> > the same error messages.
> >
> > %MUESLIX-1-STOPFAIL: Mx serial, Serial2/0 Stop Failed at disable port
> > %MUESLIX-1-STARTFAIL: Mx serial, Serial2/0 Start Failed at enable port
> >
> > no errors on the interface (line is up) but it doesn't respond.
> >
> > Serial2/0 is up, line protocol is up
> > Hardware is M1T-T3 pa
> > Internet address is x.x.x.x/x
> > MTU 4470 bytes, BW 44210 Kbit, DLY 200 usec, rely 255/255, load 1/255
> > Encapsulation HDLC, crc 16, loopback not set
> > Keepalive set (10 sec)
> > Last input 00:00:05, output 03:05:18, output hang never
> > Last clearing of "show interface" counters 00:21:23
> > Queueing strategy: fifo
> > Output queue 0/40, 40 drops; input queue 0/75, 0 drops
> > 5 minute input rate 0 bits/sec, 0 packets/sec
> > 5 minute output rate 0 bits/sec, 0 packets/sec
> > 128 packets input, 3072 bytes, 0 no buffer
> > Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
> > 0 parity
> > 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
> > 114 packets output, 3120 bytes, 0 underruns
> > 0 output errors, 0 applique, 1 interface resets
> > 0 output buffer failures, 0 output buffers swapped out
> > 2 carrier transitions
> > rxLOS inactive, rxLOF inactive, rxAIS inactive
> > txAIS inactive, rxRAI inactive, txRAI inactive
> >
> >
> > Thomas
> >
> >



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:20 EDT