RE: [nsp] a little help is required please

From: Basil Dolmatov (dol@east.ru)
Date: Thu Nov 09 2000 - 10:51:50 EST


Mamma mia... :( In order to save rick from this I overcame my laziness and
went to CISCO-MODEM-MGMT-MIB

ciscoModemMgmtMIB OBJECT IDENTIFIER ::= { ciscoMgmt 47 }
ciscoModemMgmtMIBObjects OBJECT IDENTIFIER ::= { ciscoModemMgmtMIB 1 }
cmSystemInfo OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 1 }
cmSystemInstalledModem OBJECT-TYPE
    SYNTAX Gauge32
-- Units
-- modems
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The actual number of modems that are currently installed
         within this system."
    ::= { cmSystemInfo 1 }

--------------------------------------------------------
Basil (Vasily) Dolmatov, CCIE #5347, CCNP-Security, CCDA
LightCom Corp. http://www.lightcom.ru

> -----Original Message-----
> From: Vladimir Litovka [mailto:doka@kiev.sovam.com]
> Sent: Thursday, November 09, 2000 6:37 PM
> To: rick
> Cc: Cisco-Nsp (E-mail)
> Subject: Re: [nsp] a little help is required please
>
>
> On Thu, 9 Nov 2000, rick wrote:
>
> > the total amount of lines used on a 5300.
>
> snmpwalk <router> <community> .1.3.6.1.4.1.9.2.9.2.1.1 |grep "1$" |wc -l
>
> --
> Vladimir Litovka <doka@kiev.sovam.com>
> . Phone/Fax: +380 44 4900111
> . ICQ/none, talk/none ;)
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:20 EDT