Problem of shutting down ports on 3640

From: Dragan Dincic - Dine (dine@swiftkenya.com)
Date: Fri Dec 08 2000 - 15:46:36 EST


Has anybody experienced problem of shutting down the ports - out of
nowhere?

Border.Swift.3640#sh ver
Cisco Internetwork Operating System Software
IOS (tm) 3600 Software (C3640-I-M), Version 12.0(9), RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Wed 26-Jan-00 18:23 by bettyl
Image text-base: 0x60008918, data-base: 0x60680000

ROM: System Bootstrap, Version 11.1(20)AA2, EARLY DEPLOYMENT RELEASE
SOFTWARE (fc1)

Border.Swift.3640 uptime is 33 minutes
System restarted by reload
System image file is "flash:c3640-i-mz.120-9.bin"

cisco 3640 (R4700) processor (revision 0x00) with 24576K/8192K bytes of
memory.
Processor board ID 19590345
R4700 processor, Implementation 33, Revision 1.0
Bridging software.
X.25 software, Version 3.0.0.
2 Ethernet/IEEE 802.3 interface(s)
4 Serial network interface(s)
DRAM configuration is 64 bits wide with parity disabled.
125K bytes of non-volatile configuration memory.
8192K bytes of processor board System flash (Read/Write)

Configuration register is 0x2102

Cisco 3640
with 4 serial ports (NM-4T). two of them are carrying traffic with PPP
encapsulation (512K+256) and one of them on Frame relay - satellite
connection (receive only 2Mb).
I'm trying to hook-up 4th link (also PPP - 2Mb). Two Ethernet ports. The
way how it looks is that whenever S3 comes up two PPP line protocols goes
down. Satellite link stays up.

Error on debug lokks like:
: 0x3C80295C, 0x00000000
00:27:59: %MUESLIX-1-STARTFAIL: Mx serial, Serial1/3 Start Failed at enable
port
00:28:34: %MUESLIX-1-STOPFAIL: Mx serial, Serial1/0 Stop Failed at disable
port
00:28:34: %MUESLIX-1-FAILURE_CAUSE: Serial1/0: TPU0 DMA Status address and
value

I have read trough CISCO doc. that MUESLIX-1 error is possible whenever
traffic reach about 40 Mb. (on Gigabit Ether - I do not have so much
traffic - max reach 25Mb and I do not have Gigabit Ether). Other thing that
waries me is the DMA part in error message.

Anybody familar with this error?

Dragan Dincic – Dine
Technical Manager
Swift Global (K) Ltd.
dine@swiftkenya.com
=================
P.O. BOX 42164
Nairobi, KENYA
~~~~~~~~~~~~~~~~~~~~~~~~~~~
Tel: +254 2 545 533
Fax: +254 2 545 534
~~~~~~~~~~~~~~~~~~~~~~~~~~~



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:23 EDT