only thing i see is that CEF should be enabled on s3/0 on PE2 .. (you have
disabled it)
you could try traceroute for further troubleshoouting and see where things
go wrong.
cheers,
eduard
> -----Original Message-----
> From: kevin_kuei [mailto:kevin_kuei@atnetworkinc.com]
> Sent: donderdag 21 december 2000 13:04
> To: cisco-nsp@puck.nether.net
> Subject: [nsp] [cisco-nsp] MPLS/VPN config problem
>
>
>
> Hello folks,
>
> I'm tring simple MPLS/VPN configuration in Cisco router.
> But it must be something wrong. Could you plz help me to
> troubleshooting? Thanks.
>
> My testing environment:
>
>
> [CE1]--[PE1]--[PE2]--[CE2]
>
>
> CE1:
> lo0: 192.168.101.1/24
> s0: 192.168.1.2/24
>
> PE1:
> s3/0: 192.168.1.1/24
> lo9: 11.11.11.11
> fe1/1: 10.0.0.1/24
>
> PE2:
> fe1/1: 10.0.0.2/24
> lo9: 12.12.12.12
> s3/0: 192.168.2.1/24
>
> CE2:
> s0: 192.168.2.2/24
> lo0: 192.168.102.1/24
>
> The result is: CE2 lo0 failed to reach CE1 lo0, and vice versa.. :~
>
> Plz refer to the the attachment file for more info.
>
>
> --
> Kevin Kuei
> Network Supervisor
> Core Network Team
> E_mail: kevin_kuei@atnetworkinc.com
>
>