Dear all,
12.0(13.6)S2 (PV image) was now running for more than 2 months without
any problems in our setup:
C7507/RSP4/VIP2-50s/PA-1/2FEISL/PA-A3-OC3 with dCEF enabled !
As we do have the need to increase port-density we are going into a
HW upgrade to 2 VIP4-50s with 2*PA-2FE each and 2 VIP4-80s with
2*PA-A3-OC3 each, scheduled for next Tuesday. For the new PA-2FE we
need to perform a SW upgrade to at least 12.0(14.6)S3.
Any issues with 12.0(15)S and/or VIP4/50/80, the new PA-2FEs ... ?
Any input appreciated
Tnx
CP
--- ---------------------------------------------------------------------- ---
--- Christian Panigl : Vienna University Computer Center - ACOnet ---
--- VUCC - ACOnet - VIX : -------------------------------------------- ---
--- Universitaetsstrasse 7 : Mail: Panigl@CC.UniVie.ac.at (CP8-RIPE) ---
--- A-1010 Vienna / Austria : Tel: +43 1 4277-14032 (Fax: -9140) ---
--- ---------------------------------------------------------------------- ---
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:27 EDT