Hi,
On Thu, 8 Feb 2001, Nick J. wrote:
> Does anyone know what IOS versions support using MRTG on a per VC basis?
> Otherwise I have to make a new subinterface for each pvc I want to monitor.
I believe subinterfaces don't have proper interface counters to poll.
To get per vc statistics you need following mib (snippet from mailing list
archives)
---snipp---
# http://www.geocrawler.com/archives/3/1089/2000/4/100/3581991/
#
# FROM: teleweb.pt
# DATE: 04/11/2000 05:46:00
# SUBJECT: RE: [cricket-users] ATM subinterfaces
#
# Here is my contribution for this kind of monitoring:
#
# This could be not very clarified but could help.
#
# # tree to use .1.3.6.1.4.1.9.9.66
# # add .1.1.1.1
# # than comes .1 , .2 , .3 , .4 for each of this:
# # cAal5VccInPkts, cAal5VccOutPkts, cAal5VccInOctets, cAal5VccOutOctets
# # then add .n where n=number of this slot in the cisco router (0,1,2...)
# # finally add .VPI.VCI (see in the router with the command "show atm vc")
# # This only applies for Cisco`s 7500 and 7200 series. For the LS1010 you have
# # other OID`s.
#
# Here`s an example:
# ## ATM PVC 16/32 ##
# 1.3.6.1.4.1.9.9.66.1.1.1.1.3.1.16.32 - cAal5VccInOctets
# 1.3.6.1.4.1.9.9.66.1.1.1.1.4.1.16.32 - cAal5VccOutOctets
#
# ## ATM SVC 0/108 SERVER FARM ##
# 1.3.6.1.4.1.9.9.66.1.1.1.1.3.1.0.108 - cAal5VccInOctets
# 1.3.6.1.4.1.9.9.66.1.1.1.1.4.1.0.108 - cAal5VccOutOctets
#
# As always you could browse the mib to look for some interesting oid`s to
# monitor.
---snipp---
we are currently polling per vc in and out bytes from 7206 ciscos with PA-A1
running 12.0S(14). The mib was broken somewhere in 12.0.S(12..13)
Greetings
Christian
-- TopLink Internet Services GmbH ck@171.2.195.in-addr.arpa Christian Kratzer http://www.toplink.net/ Phone: +49 7032 2701-0 Fax: +49 7032 2701-19 FreeBSD spoken here!
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:28 EDT