Re: [nsp] Cisco 7206-VXR disaster recovery.

From: Barry Bruins (bbruins@cisco.com)
Date: Mon Feb 26 2001 - 09:19:26 EST


If your router has no image on flash and no image on boot flash then
you don't have a way to use tftp. The rommon doesn't have tftp in it.
You will have to get a flash card with an image on it to boot from.

Barry

At 07:11 PM 2/26/2001 +0530, Vinod Anthony Joseph Cherunni wrote:

>Dear David,
>
>Thanks so much for the reply, I tried connecting the TFTP server directly to the Fast-Ethernet interface on the NPE 300, & issued the command "boot c7200-js-mz.121-6.bin 192.168.1.1" I recieve the following error message
>
>" An alternate boot helper program is not specified (monitor variable "BOOTLDR" is not set) and unable to determine first file in boot flash load prog% error - on file open boot % cannot load "c7200-js-mz.121-6.bin 192.168.129.1".
>
>I do not find any vaild images on any of the flash disks, & the system is totally empty.
>
>I forgot to mention, that the router is currently stuck in ROM-Monitor mode.
>
>Kindly advise me on what could be done.
>
>With warm regards,
>Vinod.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:30 EDT