IIRC, the NM-2FE2W is not supported at all in the 26xx series.
-Chris
-----Original Message-----
From: Majid [mailto:MRouhani@takta.net]
Sent: Saturday, April 14, 2001 5:14 PM
To: cisco-nsp@puck.nether.net
Subject: [nsp] Undefined Port Adapter type xxx !!
Importance: High
Hi
I have three NM-2FE2W installed in C2620, C3620 and C3662
but 2620 doesn't recognize it at all, 3620 which is running
enterprise IOS and 3662 have no problems yet, meanwhile 3662
refused NM-4E with one the newest IOS i had.
---------------------------------------------------------
cisco2620> sh diag
....
Slot 1:
Unknown (type 216) Port adapter
Port adapter is disabled
....
failed with : 12.0(7)T IP (c2600-i-mz.120-7.T.bin)
failed with : 12.1(3)T IP (c2600-i-mz.121-3.T.bin)
failed with : 12.1(5)T5 IP (c2600-c-mz.121-5.T5.bin) !!
status : still i have problem with this module
---------------------------------------------------------
cisco3620> sh diag
....
Slot 1:
NM-2FE2W Port adapter, 4 ports
Port adapter is analyze
....
running: 12.1(3a)T1 Enterprise/FW/IDS Plus IPSec 3DES
(c3620-jk2o3s-mz.121-3a.T1.bin)
status : no problem at all
----------------------------------------------------------
cisco3662> sh diag
....
Slot 1:
NM-2FE2W Port adapter, 3 ports
Port adapter is analyzed
....
Slot 3:
Unknown (type 215) Port adapter
Port adapter is disabled
....
running : 12.1(3)T IP (c3660-i-mz.121-3.T.bin)
failed with : 12.1(5)T6 IP (c3660-i-mz.121-5.T6.bin) !!
status : no problem with NM-2FE2W but NM-4E failed with
12.1(5)T6 that i have to upgrade to 12.1(5)xx
cause of new features i need.
---------------------------------------------------------
2600/3600 with minimum software requirements for NMs ( click
<http://www.cisco.com/univercd/cc/td/doc/product/access/acs_mod/cis2600/net_
mod2/ovrnetm.htm> here)
anybody came across this before ?
Thanks,
Majid
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:34 EDT