Re: [nsp] 7513 crash

From: Siva Valliappan (svalliap@cisco.com)
Date: Tue May 01 2001 - 16:23:04 EDT


you can also send me the crashinfo file on a unicast, and i will try
to look at it and give you some feedback. no guarantees on when i
will be able to reply :)

regards
.siva

>
> Hi,
>
> On Tue, May 01, 2001 at 05:00:04AM -0700, Siva Valliappan wrote:
> > it goes into bootflash. it is automatically enabled. what does
> > "dir bootflash:" say?
>
> Yes, it's there. I'll try to send this down our normal Cisco problem
> reporting channels (that doesn't seem to work right now, but that's a
> different issue *sigh*).
>
> Cisco-M#dir bootflash:
> Directory of bootflash:/
>
> 1 -rw- 4462908 Mar 15 1917 18:40:05 c7200-kboot-mz.121-3a.E5
> 2 -rw- 202010 Apr 30 2001 11:05:10 crashinfo_20010430-090510
>
> 7602176 bytes total (2937000 bytes free)
>
> thanks for explaining to me.
>
> > i think the bug about the incorrect reporting
> > might be known and fixed, need to check....
>
> Can't check with different versions - all other boxes only have
> "slot0:", and it does NOT happen for them.
>
> gert
> --
> Gert Doering
> Mobile communications ... right now writing from *@Bologna*
> ... mobile phone: +49 177 2160221 ... or mail me: gert@greenie.muc.de
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:36 EDT