RE: New Error Message on Cat 4000

From: KF (kf@reign.sk)
Date: Wed Jun 06 2001 - 10:13:46 EDT


Yo, something like that I've saw long time ago. It was the Flow Control on
Gigabit Ethernet interface, setted to desirable or auto ;) pain in the ass,
but I remember that, it helps to set ON, depended ofcourse on remote node if
device is Cisco or not...

might help ;)

Alex

-----Original Message-----
From: Bill Carter [mailto:bcarter@family-net.net]
Sent: Wednesday, June 06, 2001 3:57 PM
To: cisco puck
Subject: New Error Message on Cat 4000

This message popped up today on a Catalyst 4000.

%SYS-4-P2_WARN:1/Blocked queue on gigaport 7, ( 0 : 3729 )

I can't find anything on CCO regarding this message. This started at
4:00AM and continued until I reset the box. I'm running 5.5(7).

Thanks,
Bill