On Wed, Jun 20, 2001 at 07:03:35PM -0700, Siva Valliappan wrote:
> there is probably 2 separate issues going on. i saw that the original
> post was a router running 11.2. could be a carrier problem, or could
> be something else. not enough information to determine what is going on.
>
> in your case, the reason is as follows:
>
> the mueslix code on the PAs were pretty trashed recently during an
> optimization / enhancment effort.
>
> CSCdm70067 was designed to enhance the performance of the mueslix PAs,
> and caused various issues :(
>
> most of this was backed out via CSCdt10216
>
> which greatly reduces the number of interface resets/carrier transitions
> and so forth that occur when doing NVRAM and related commands while
> passing heavy traffic over a mueslix based PA (with several other
> requirements).
>
> there are
>
> CSCdt69653
> CSCdt71082
> CSCdt10216
^^^^^^^^^^ - Yay.. my bug :)
Workaround for that one is to load 12.0(10)S
My tac case got so long they had to open a new one as the
case history was full.
- Jared
-- Jared Mauch | pgp key available via finger from jared@puck.nether.net clue++; | http://puck.nether.net/~jared/ My statements are only mine.