RE: No netflow on port 1 or 2 of Trident 3GE in GSR?

From: Martin, Christian (cmartin@gnilink.net)
Date: Tue Aug 21 2001 - 17:32:41 EDT


Dani,

Are you looking to observe the netflow cache from the CLI? If so, you must
attach to the LC slot and execute the command from there. As far as export
goes, this is controlled by the GRP itself - funny how the GRP can send
exported flows but cannot tabulate them for the cli...

attach <slot>

LC_Slotx>en
LC_Slotx#show ip cache flow
..
..
..
<snip>

regards,
chris

> -----Original Message-----
> From: Dani Roisman [mailto:dani@roisman.com]
> Sent: Tuesday, August 21, 2001 12:36 PM
> To: cisco-nsp@puck.nether.net
> Subject: No netflow on port 1 or 2 of Trident 3GE in GSR?
>
>
> Hello,
>
> We've just upgraded to 12.0.16S3, and still cannot get any netflow off
> ports giX/1 or giX/2 of our Trident 3GE cards in our GSR
> 12012 routers.
> The release notes for 12.0.16S3 claims to have fixed bug CSCdu72555,
> but it looks like that's not the case.
>
> I'm making a call out to anyone else who has this problem, we aren't
> making any progress elsewhere, this might help us understand if we're
> the only ones experiencing this.
>
> If you are able to reply privately to me with TAC trouble tickets, or
> reply back to the list with your remedies for this problem, that would
> be helpful.
>
> Thank you
>
> - Dani
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:50 EDT