What does "sh bootv" say?
- jared
On Fri, Oct 05, 2001 at 05:14:21PM -0400, jlewis@lewis.org wrote:
> Anyone know why this 7200 might be refusing to honor boot system config
> commands? I've got other 7200's and have never seen them do this before.
>
> *Jan 24 09:58:29: %SYS-5-RELOAD: Reload requested
> System Bootstrap, Version 12.0(19990210:195103) [12.0XE 105], DEVELOPMENT SOFTWA
> RE
> Copyright (c) 1994-1999 by cisco Systems, Inc.
> C7200 platform with 262144 Kbytes of main memory
>
>
> Self decompressing the image : #################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ######### [OK]
>
> %SYS-4-CONFIG_NEWER: Configuration from version 12.1 may not be correctly unders
> tood
> %SYS-6-READ_BOOTFILE_SKIP: boot system slot1:c7200-p-mz.121-5.T10.bin command is
> skipped
>
> %SYS-6-READ_BOOTFILE_SKIP: boot system slot0:c7200-p-mz.121-5.T8.bin command is
> skipped
>
> %SYS-6-READ_BOOTFILE_SKIP: boot system slot1:c7200-p-mz.121-5.T8.bin command is
> skipped
>
> %DEC21140-5-NOCARR: FastEthernet0/2/0 cable/connector problem?
> %DEC21140-5-NOCARR: FastEthernet0/2/0 cable/connector problem?
> %SYS-6-BOOT_MESSAGES: Messages above this line are from the boot loader.
> Self decompressing the image : #################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ################################################################################
> ############################################### [OK]
>
> Restricted Rights Legend
>
> Use, duplication, or disclosure by the Government is
> subject to restrictions as set forth in subparagraph
> (c) of the Commercial Computer Software - Restricted
> Rights clause at FAR sec. 52.227-19 and subparagraph
> (c) (1) (ii) of the Rights in Technical Data and Computer
> Software clause at DFARS sec. 252.227-7013.
>
> cisco Systems, Inc.
> 170 West Tasman Drive
> San Jose, California 95134-1706
>
>
>
> Cisco Internetwork Operating System Software
> IOS (tm) 7200 Software (C7200-P-M), Version 12.1(5)T8, RELEASE SOFTWARE (fc1)
> TAC Support: http://www.cisco.com/cgi-bin/ibld/view.pl?i=support
> Copyright (c) 1986-2001 by cisco Systems, Inc.
> Compiled Tue 08-May-01 09:35 by ccai
> Image text-base: 0x60008960, data-base: 0x6109C000
>
> cisco 7206VXR (NPE300) processor (revision D) with 253952K/40960K bytes of memor
> y.
> Processor board ID 20400142
> R7000 CPU at 262Mhz, Implementation 39, Rev 2.1, 256KB L2, 2048KB L3 Cache
> 6 slot VXR midplane, Version 2.0
>
> Last reset from power-on
> X.25 software, Version 3.0.0.
> 2 FastEthernet/IEEE 802.3 interface(s)
> 2 Serial network interface(s)
> 125K bytes of non-volatile configuration memory.
>
> 20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
> 20480K bytes of Flash PCMCIA card at slot 1 (Sector size 128K).
> 4096K bytes of Flash internal SIMM (Sector size 256K).
>
>
> Press RETURN to get started!
>
>
> 00:00:31: %LINK-3-UPDOWN: Interface FastEthernet0/0, changed state to up
> 00:00:31: %LINK-3-UPDOWN: Interface FastEthernet2/0, changed state to up
> 00:00:31: %LINK-3-UPDOWN: Interface Serial3/0, changed state to down
> 00:00:31: %LINK-3-UPDOWN: Interface Serial3/1, changed state to down
> *Jan 24 10:01:01: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/
> 0, changed state to up
> *Jan 24 10:01:01: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet2/
> 0, changed state to down
> *Jan 24 10:01:01: %LINEPROTO-5-UPDOWN: Line protocol on Interface Serial3/0, cha
> nged state to down
> *Jan 24 10:01:01: %LINEPROTO-5-UPDOWN: Line protocol on Interface Serial3/1, cha
> nged state to down
> *Jan 24 10:01:02: %LINK-5-CHANGED: Interface FastEthernet2/0, changed state to a
> dministratively down
>
> User Access Verification
>
> Password:
> Router>ena
> Password:
> Router#sh conf
> Using 1762 out of 129016 bytes
> !
> version 12.1
> no service single-slot-reload-enable
> service timestamps debug datetime
> service timestamps log datetime
> service password-encryption
> !
> hostname Router
> !
> boot system flash slot1:c7200-p-mz.121-5.T10.bin
> boot system flash slot0:c7200-p-mz.121-5.T8.bin
> boot system flash slot1:c7200-p-mz.121-5.T8.bin
> logging rate-limit console 10 except errors
> enable secret 5 $1$qMMJ$yT4rPFmz5PRRlXx3PVjlw/
> !
> ...
>
> Router#sh slot0:
> -#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
> 1 .. image 84C0659C 9C0A50 23 10095056 Sep 24 2001 12:24:16 c7200-p-mz.1
> 21-5.T8.bin
>
> 10483120 bytes available (10095184 bytes used)
> Router#sh slot1:
> -#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
> 1 .. image 84C0659C 9C0A50 23 10095056 Jan 24 1918 08:48:07 c7200-p-mz.1
> 21-5.T8.bin
> 2 .. image 14F4D8A9 1361AB8 24 10096616 Jan 24 1918 09:26:53 c7200-p-mz.1
> 21-5.T10.bin
>
> 386376 bytes available (20191928 bytes used)
> Router#sh ver
> Cisco Internetwork Operating System Software
> IOS (tm) 7200 Software (C7200-P-M), Version 12.1(5)T8, RELEASE SOFTWARE (fc1)
> TAC Support: http://www.cisco.com/cgi-bin/ibld/view.pl?i=support
> Copyright (c) 1986-2001 by cisco Systems, Inc.
> Compiled Tue 08-May-01 09:35 by ccai
> Image text-base: 0x60008960, data-base: 0x6109C000
>
> ROM: System Bootstrap, Version 12.0(19990210:195103) [12.0XE 105], DEVELOPMENT S
> OFTWARE
> BOOTFLASH: 7200 Software (C7200-BOOT-M), Version 12.0(18)S, EARLY DEPLOYMENT REL
> EASE SOFTWARE (fc1)
>
> Router uptime is 1 minute
> System returned to ROM by reload at 09:58:28 UTC Thu Jan 24 1918
> System image file is "slot0:c7200-p-mz.121-5.T8.bin"
>
> cisco 7206VXR (NPE300) processor (revision D) with 253952K/40960K bytes of memor
> y.
> Processor board ID 20400142
> R7000 CPU at 262Mhz, Implementation 39, Rev 2.1, 256KB L2, 2048KB L3 Cache
> 6 slot VXR midplane, Version 2.0
>
> Last reset from power-on
> X.25 software, Version 3.0.0.
> 2 FastEthernet/IEEE 802.3 interface(s)
> 2 Serial network interface(s)
> 125K bytes of non-volatile configuration memory.
>
> 20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
> 20480K bytes of Flash PCMCIA card at slot 1 (Sector size 128K).
> 4096K bytes of Flash internal SIMM (Sector size 256K).
> Configuration register is 0x2102
>
>
> --
> ----------------------------------------------------------------------
> Jon Lewis *jlewis@lewis.org*| I route
> System Administrator | therefore you are
> Atlantic Net |
> _________ http://www.lewis.org/~jlewis/pgp for PGP public key_________
-- Jared Mauch | pgp key available via finger from jared@puck.nether.net clue++; | http://puck.nether.net/~jared/ My statements are only mine.