What rev of IOS did this show up in?
Thanks,
Charles
On Wed, 17 Oct 2001, Roy wrote:
> The card will go full duplex but won't properly autodetect with many switches.
> Manually set both the router and switch to full duplex
>
> "Ishikawa, Tom" wrote:
>
> > Hi all,
> >
> > Does NM-1E2W card able to do Full-dplex?
> > Below is my set up.
> >
> > c3604(NM-1E2W)10/full ---- c3512(F0/3)10/full.
> >
> > When I do this, I get
> >
> > "%CDP-4-DUPLEX_MISMATCH: duplex mismatch discovered on FastEthernet0/3(not
> > half duplex), with c3604 Ethernet0/0 (half duplex).5"
> > and
> > "%CDP-4-DUPLEX_MISMATCH: duplex mismatch discovered on Ethernet0/0 (not full
> > duplex), with c3512 FastEthernet0/3 (full duplex)."
> >
> > When I change my setting to
> >
> > c3604(NM-1E2W)10/full ---- c3512(F0/3)auto/auto
> >
> > It gets detected as 10/half on the switch side.
> >
> > any idea?
> >
> > -tishi
>
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:51 EDT