RE: Odd T1 problem

From: Scott.Keoseyan@BroadWing.com
Date: Thu Dec 27 2001 - 09:26:18 EST


I'm confused... if it is going into a DACS, don't they have to frame it, or
at least agree on the framing type because they're going to have option-able
CO equipment? I could see if it was simply in/out on a central-office frame
that you wouldn't want them to do anything to it...

Scott

-----Original Message-----
From: Jim Warner [mailto:warner@cats.UCSC.EDU]
Sent: Thursday, December 27, 2001 12:53 AM
To: jlertora@thurmans.com; jlewis@lewis.org
Cc: cisco-nsp@puck.nether.net
Subject: Re: Odd T1 problem

jlewis said, with respect to the appropriate phone company:

> They claim they've verified it (ESF/B8ZS) on all their gear this circuit
> goes through.

What you want from the phone company is "clear channel" and B8ZS.
You do not what them to run ESF or to fiddle with your framing
in any way on a point-to-point link. Often it is in your interest
to tell the phone company that you will be using ESF because they
can passively monitor your stream for CRC-6 errors and tell you
what they see at their intermediate points. But they shouldn't
configure their equipment for ESF -- if that means terminating your
framing and generating their own.

-jim warner, UCSC

 
+++The information transmitted is intended only for the person or entity to
which it is addressed and may contain confidential and/or privileged
material. Any review, retransmission, dissemination or other use of, or
taking of any action in reliance upon, this information by persons or
entities other than the intended recipient is prohibited. If you received
this in error, please contact the sender and destroy any copies of this
document.+++



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:58 EDT